Requirements for a NOON Multi-Way Configuration
Installing NOON switching in a multi-way configuration does come with a few requirements. Continue reading to better prepare yourself prior to installing your NOON switches.
-
NOON switches can be installed on multi-way configurations of up to four switches.
-
All switches in a multi-way circuit must be replaced with NOON switches.
-
NOON requires all switches in a multi-way configuration to be wired hot (in a parallel circuit).
-
Ground wires are required in all multi-way switch locations.
-
Neutral wires are required in all multi-way switch locations.*
-
3-wire cables between multi-way switches are required, including two travelers and one common wire.
NOTE: For dead-end configured multi-way circuits, where one junction box does not have any neutral wires passing through, you can repurpose one of the travelers as a neutral (where code permits). See below for more details on how to install in this configuration: